| Electrical data |
|---|
| Operating voltage [V] | 10...36 DC |
| Current consumption [mA] | 10; (24 V) |
| Protection class | II |
| Reverse polarity protection | yes |
| Outputs |
|---|
| Electrical design | PNP |
| Output function | normally open |
| Max. voltage drop switching output DC [V] | 2.5 |
| Permanent current rating of switching output DC [mA] | 100 |
| Switching frequency DC [Hz] | 800 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
| Detection zone |
|---|
| Sensing range [mm] | 7 |
| Real sensing range Sr [mm] | 7 ± 10 % |
| Operating distance [mm] | 0...5.7 |
| Increased sensing range | yes |
| Accuracy / deviations |
|---|
| Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.4 / copper: 0.3 |
| Hysteresis [% of Sr] | 3...15 |
| Switch point drift [% of Sr] | -10...10 |
| Operating conditions |
|---|
| Ambient temperature [°C] | 0...100 |
| Protection | IP 68; IP 69K; ("COP") |
| Tests / approvals |
|---|
| EMC | | EN 61000-4-2 ESD | 4 kV CD / 8 kV AD | | EN 61000-4-3 HF radiated | 10 V/m | | EN 61000-4-4 Burst | 2 kV | | EN 61000-4-6 HF conducted | 10 V | | EN 55011 | class B |
|
| MTTF [years] | 2006 |
| UL approval | | Ta | 0...40 °C | | Enclosure type | Type 1 | | voltage supply | Limited Voltage/Current | | File number UL | E174191 |
|
| Mechanical data |
|---|
| Weight [g] | 25.8 |
| Housing | threaded type |
| Mounting | non-flush mountable |
| Dimensions [mm] | M12 x 1 / L = 50 |
| Thread designation | M12 x 1 |
| Materials | threaded sleeve: stainless steel (1.4404 / 316L); sensing face: PEEK; lock nuts: stainless steel |
| Displays / operating elements |
|---|
| Display | | switching status | 4 x 90° LED, yellow |
|
| Accessories |
|---|
| Accessories (supplied) | |
| Remarks |
|---|
| Pack quantity | 1 pcs. |
| Electrical connection - plug |
|---|
| Connection | Connector: 1 x M12; Contacts: gold-plated |